Insulated Wire Cable
- Voltage:Rated voltage:600V, test voltage:2000V
- Conductor:Silver plated copper/Nickel plated copper
- Insulation:polyimide/PTFE/Silicone rubber
- Cores:single
- Standard:iec/astm etc
- Packaging:Iron or wooden drum
Twin and Earth Cable
Twin and earth cable comprises two individually insulated current carrying conductors and an uninsulated circuit protective conductor. Twin and Earth cable is the most common cable used for domestic wiring today.The sheath is either grey (PVC) or white for low smoke cables (OHLS).
Flat Twin and Earth
Also known as FTE (flat twin and earth) the live and neutral conductors are individually insulated, and the Circuit Protective Conductor (CPC) or earth, is bare. Not suitable for unprotected use outside as the outer sheath materials are vulnerable to attack by UV although protective paint can provide some UV protection.
Standard metric twin and earth cable sizes are
- 1mm² 1.5mm² & 2.5mm² which have solid (non-stranded) conductors
- 4mm², 6mm², 10mm², 16mm² and higher have stranded conductors
- 1.5mm² is used typically for domestic wiring circuits and 2.5mm² twin and earth is used in domestic power circuits
Flat Twin & Earth Cable Parameter
Conductor | Insulation thickness (mils) | Sheath thickness (mils) | Norminal O.D. (mils) | Approx. Mass kg/km |
stranding No./mm | ||||
2×1/1.13 | 0.6 | 0.9 | 6.6×4.2 | 55 |
2×7/0.50 | 0.6 | 0.9 | 7.4×4.7 | 80 |
2×7/0.67 | 0.7 | 1 | 9.0×5.6 | 125 |
2×7/0.85 | 0.8 | 1.1 | 10.7×6.6 | 155 |
2×7/1.04 | 0.8 | 1.1 | 11.8×7.2 | 215 |