7/32” (5.69 mm) Monoconductor

logging-cable-1
  • Cable Diameter:
  • 0.224” +0.005” – 0.002” (5.69mm +0.13mm -0.05mm)
  • Minimum Sheave Diameter:
  • 14” (36cm)
  • Cable Stretch Coefficient:
  • 2.2 ft/kft/Klbs (2.5 m/Km/5KN)
  • Maximum Conductor Voltage:
  • 1,200 VDC
  • Conductor AWG Rating:
  • 16
  • Minimum Insulation Resistance:
  • 1,500 MegaΩ/Kft @ 1000VDC (457 Mega Ω/Km @ 1000VDC)
  • Armor Electrical Resistance:
  • 4.3 Ω/Kft (14.1 Ω/Km)

MECHANICAL

  • Cable Breaking Strength:
  • Ends Fixed: 5,600 lbs (24.9 KN) Nominal
  • Maximum Suggested Working Tension: 2,800 lbs (12.5 KN)
  • Number and Size of Wires:
  • Inner Armor 15 x 0.0243”(0.617 mm)
  • Outer Armor 15 x 0.0358” (0.909 mm)
  • Average Wire Breaking Strength:
  • Inner Armor 132 lbs (0.59 KN)
  • Outer Armor 286 lbs (1.27 KN)
Core DescriptionCable Weight
Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
°FininΩ/Kftpf/ftinlbs/Kft
°CmmmmΩ/Kmpf/mmmKg/Km
300*Poly0.024519x0.01194.1600.1089175
149*0.62219x0.30213.51972.743136112
420*ETFE0.011519x0.01194.1610.1089276
216*0.29219x0.30213.52002.743137114
420*TPX0.01319x0.011941610.0859276
216*0.3319x0.30213.52002.159137114
500*ETFE0.011519x0.01194.1580.1089578
260*0.29219x0.30213.51902.743140116
500*FEP0.01319x0.01194.1580.0859578
260*0.3319x0.30213.51902.159140116
  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed.
  • Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68° F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
  • SUPERSEAL, a special pressure seal agent, is applied between armor layers.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • All values shown are nominal or typical values.

5/16″ (8.18 mm) Monoconductor

logging-cable-2
  • Cable Diameter:
    0.322″ +0.005″ – 0.002″ (8.18 mm +0.13 mm -0.05mm)
  • Minimum Sheave Diameter:
  • 18″ (46 cm)
  • Cable Stretch Coefficient:
  • 1.2 ft/Kft/Klbs (1.35 m/Km/5KN)
  • Maximum Conductor Voltage:
  • 1,500 VDC
  • Conductor AWG Rating:
  • 15
  • Minimum Insulation Resistance:
  • 1,500 MegaΩ/Kft @ 1,000 VDC (457 MegaΩ/Km @ 1000VDC)
  • Armor Electrical Resistance:
  • 2.1 Ω/Kft (6.9 Ω/Km)

MECHANICAL

  • Cable Breaking Strength:
  • Ends Fixed: 14,750 65.63 KN) Nominal
  • Maximum Suggested Working Tension: 7,375 (32.7 KN)
  • Number and Size of Wires:
  • Inner Armor 12 x 0.0445”(1.130 mm)
  • Outer Armor 18 x 0.0445” (1.130 mm)
  • Average Wire Breaking Strength:
  • Inner Armor 564(2.5 KN)
  • Outer Armor 564(2.5 KN)
Core DescriptionCable Weight
Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
°FininΩ/Kftpf/ftinlbs/Kft
°CmmmmΩ/Kmpf/mmmKg/Km
300*Poly0.04219x0.01422.8480.155187155
149*1.06719x0.3619.21583.937278230
500*ETFE0.017519x0.01422.8460.155194160
260*0.44519x0.3619.21513.048288238
500*FEP0.024519x0.01422.8460.12194160
260*0.62219x0.3619.21513.048288238
  • See attached specification sheet for recommended maximum temperature exposure times.
  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed.
  • Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68° F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
  • SUPERSEAL, a special pressure seal agent, is applied between armor layers.
  • The temperature rating assumes a normal gradient for both temperature and weight. All values shown are nominal or typical values.

9/32” (7.32 mm) Monoconductor

logging-cable-3
  • Cable Diameter:
  • 0.288” +0.005” – 0.002” (7.32mm + 0.13mm -0.05mm)
  • Minimum Sheave Diameter:
  • 16” (41 cm)
  • Cable Stretch Coefficient:
  • 1.55 ft/Kft/Klbs (1.74 m/Km/5KN)
  • Maximum Conductor Voltage:
  • 1,500 VDC
  • Conductor AWG Rating:
  • 15
  • Minimum Insulation Resistance:
  • 1,500 MegaΩ/Kft @ 1000VDC (457 MegaΩ/Km @ 1000VDC)
  • Armor Electrical Resistance:
  • 2.8 Ω/Kft (9.2 Ω/Km)

MECHANICAL

  • Cable Breaking Strength:
  • Ends Fixed: 10,200 lbs (45.4 KN) Nominal
  • Maximum Suggested Working Tension: 5,100 lbs (22.7 KN)
  • Number and Size of Wires:
  • Inner Armor 12 x 0.0400”(1.016 mm)
  • Outer Armor 18 x 0.0400”(1.016 mm)
  • Average Wire Breaking Strength:
  • Inner Armor 393 lbs (1.75 KN)
    Outer Armor 393 (1.75 KN)
Core DescriptionCable Weight
Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
°FininΩ/Kftpf/ftinlbs/Kft
°CmmmmΩ/Kmpf/mmmKg/Km
500*ETFE0.01919x0.01422.8500.136157130
260*0.48319x0.3619.21803.454234234
500*FEP0.013519x0.01422.8500.098157130
260*0.34319x0.3619.21802.489234193
300*Poly0.032519x0.01422.8560.136152126
149*0.82619x0.3619.21843.454226187
420*Camtane0.013519x0.01422.8550.098155128
216*0.34319x0.3619.21842.489230190
420*ETFE0.01919x0.01422.8550.136155128
216*0.48319x0.3619.21843.454230190