0,6/1 kV XGB Cable

06-1-kV-XGB-Cable
  • Rated voltage: 0,6/1 kV
  • Conductors: Cu annealed conductors, class 1 or class 2
  • Insulation: XLPE compound DIX 1
  • Bedding: Extruded elastomere or plastomere compound or plastic tape
  • Sheath: LS0H compound, type G
  • Bending radius (min): single-core – 15D; multicore – 12D
  • Min. laying temperature: 0°C
  • Operating temperature: -15°C to 60°C
  • Max. conductor temperature: 90°C
  • Max. short-circuit temperature: 250°C
  • Flame propagation: EN 60332-1-2
  • Fire propagation: EN 50339, EN 60332-3-24
  • Low emission of halogen and corrosive gases:
  • EN 60754-1 i EN 60754-2
  • Smoke density: EN 61034-2
  • Sheath Colour: available on request

APPLICATION: XGB are fire retardant power cables for domestic and industrial applications with a voltage rating of 1kV. This product range is suitable for use indoor and outdoor, protected by ducts for mechanical and UV protection.

XGB-F2 0.6/1kV Cable

  • Rated voltage: 0,6/1 kV
  • Conductor: Class 1 Solid copper , Class 2 Stranded copper
  • Insulation: XLPE (Cross-Linked Polyethylene)
  • Filler: Filling compound or HF tape (Halogen free)
  • Inner Sheath: Filling compound or tape
  • Outer Sheath: HF Thermoplastic (Halogen free)
  • Sheath Colour: Green
  • Temperature Rating:
  • Operating: -15ºC to +60ºC
  • Minimum Installation: 0ºC
  • Maximum conductor temperature in service: +90ºC
  • Minimum Bending Radius: 12 x overall diamater

APPLICATION: Installation cable for buildings with high concentrations of people or valuable equipment, especially in difficult evacuation conditions. This cable can be used in cable conduit, cable duct, embedded in concrete, cement or walls. It can also be used in open air protected from direct UV rays, in industries and houses. Underground installation is allowed provided the cable is installed in a sufficiently drained tube.

XGB Cca 0,6/1kV Cable

XGB-Cca-06-1kV
  • Design:
  • 1 Copper core, solid (Class 1) or stranded (Class 2) depending on cross-section 1.
  • 2 Cross-linked polyethylene (XLPE) insulation (X) 2.
  • 3 Filling compound or tape halogen-free 3.
  • 4 Outer sheath in halogen-free thermoplastic material (G) – Colour: GREEN 4.
  • Installation:
  • 1 In cable conduit
  • 2 In cable duct
  • 3 Embedded in concrete, cement or walls
  • 4 In open air
  • 5 In industries
  • 6 In houses
  • 7 Underground installation is allowed provided the cable is installed in a sufficiently drained tube

0,6/1 kV XGB Cable Technical Date

NOMINAL CROSS SECTION CONDUCTOR SHAPE MAX. RESISTANCE AT 20°C CABLE WEIGHT (APPROX.)
mm² Ω/km kg/km
1×1,5 RE 12,1 45
1×2,5 RE 7,41 58
1×4 RE 4,61 77
1×6 RE 3,08 100
1×10 RE 1,830 145
1×16 RM 1,150 210
1×25 RM 0,727 312
1×35 RM 0,524 418
2×1,5 RE 12,1 159
2×2,5 RE 7,41 197
2×4 RE 4,61 251
2×6 RE 3,08 316
3×1,5 RE 12,1 178
3×2,5 RE 7,41 227
3×4 RE 4,61 295
3×6 RE 3,08 379
3×25+16 RM/RE 0,727/1,150 1264
3×35+16 RM/RE 0,524/1,150 1637
4×1,5 RE 12,1 205
4×2,5 RE 7,41 264